  cui .com date 03/12/2013 page 1 of 4 series : vawq6 description: dc-dc converter date 03/12/2013 page 1 of 4 features ? up to 6 w isolated output ? wide input (4:1) ? industry standard 24 pin dip package style ? single and dual regulated outputs ? 3,000 v isolation (h version) ? short circuit protection ? wide temperature (-25~71c) ? efficiency up to 80% rohs model input voltage output voltage output current output power ripple and noise 1 effciency typ (vdc) range (vdc) (vdc) max (ma) max (w) max (mvp-p) typ (%) vawq6-q24-s3r3 24 9~36 3.3 1,000 3.3 100 72 vawq6-q24-s5 24 9~36 5 1,000 5 100 78 vawq6-q24-s12 24 9~36 12 470 5.64 120 80 vawq6-q24-s15 24 9~36 15 400 6 150 80 vawq6-q24-d5 24 9~36 5 500 5 100 78 VAWQ6-Q24-D12 24 9~36 12 230 5.52 120 80 vawq6-q24-d15 24 9~36 15 190 5.7 150 80 vawq6-q48-s3r3 48 18~72 3.3 1,000 3.3 100 70 vawq6-q48-s5 48 18~72 5 1,000 5 100 78 vawq6-q48-s12 48 18~72 12 470 5.64 120 79 vawq6-q48-s15 48 18~72 15 400 6 150 80 vawq6-q48-d5 48 18~72 5 500 5 100 77 vawq6-q48-d12 48 18~72 12 230 5.52 120 79 vawq6-q48-d15 48 18~72 15 190 5.7 150 80 notes: 1. ripple and noise are measured at 20 mhz bw with 10f tantalum capacitor and 1f ceramic capacitor across output part number key vawq6 - q xx - x xx h input voltage output voltage base number isolation voltage: h = 3,000 vdc output: s = single d = dual
cui .com date 03/12/2013 page 2 of 4 cui inc series : vawq6 description: dc-dc converter input parameter conditions/description min typ max units operating input voltage 12 v model 24 v model 9 18 24 48 36 72 vdc vdc input flter pi type output parameter conditions/description min typ max units line regulation measured from low line to high line 0.5 % load regulation single output models 1 dual output models 2 0.5 1.0 % % voltage accuracy 2.0 % voltage balance dual output models 1.0 % switching frequency 200 khz temperature coeffcient 0.05 %/c notes: 1. measured from 10% to 100% full load 2. measured from 25% to 100% full load protections parameter conditions/description min typ max units short circuit protection continuous safety and compliance parameter conditions/description min typ max units isolation voltage 3,000 vdc insulation resistance 1,000 m? rohs compliant yes environmental parameter conditions/description min typ max units operating temperature -25 71 c case temperature 95 c storage temperature -40 100 c note: all specifcations are typical measured at nominal line, full load, and 25c unless otherwise noted
cui .com date 03/12/2013 page 3 of 4 cui inc series : vawq6 description: dc-dc converter 1 bott om view 2 3 24 23 22 16 15 14 13 9 10 11 12 31.8 [1.25] 15.24 [0.600] 20.3 [0.80] 2.54 [0.100] 3.8 [0.15] 10.2 [0.40] se e note 2.0 [0.08] mechanical drawing mechanical parameter conditions/description min typ max units dimensions 1.25 x 0.80 x 0.40 (31.8 x 20.3 x 10.2 mm) inch case material non-conductive black plastic weight 12.5 g 100 80 60 40 20 ambient t emper ature (c) load (% ) -40- 20 02 04 06 07 1 95 120 derating curves pin connections single output dual output pin function function 1,24 np np 2,3 -vin -vin 4,5 np np 9 nc common 10,15 nc nc 11 nc -vo 12,13 np np 14 +vo +vo 16 -vo common 20,21 np np 22,23 +vin +vin units: mm [inches] tolerance: inches: x.xx = 0.02, x.xxx = 0.010 mm: x.xx = 0.5, x.xxx = 0.25 note: pin diameter 0.02 inch (0.5 mm) np = no pin nc = no connection note: all specifcations measured at 25c, nominal input voltage, and full load unless otherwise noted.
date 03/12/2013 page 4 of 4 cui inc series : vawq6 description: dc-dc converter cui offers a two (2) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 10/13/2008 1.01 updated information 04/09/2009 1.02 updated to new template 08/22/2011 1.03 v-infnity branding removed 09/11/2011 1.04 updated spec 03/12/2013 the revision history provided is for informational purposes only and is believed to be accurate. revision history


▲Up To Search▲   

 
Price & Availability of VAWQ6-Q24-D12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X